Geotechnical Calculations
Seismic Zone
Drop a pin anywhere in Bangladesh to get its BNBC 2020 seismic zone and Z value, with a warning near zone lines.
The BNBC 2020 basic wind speed for a site, and the velocity pressure qz at each height of a building.
The tool gives a first answer. For a design solution for your own building or site, send your result and a few details to a Civilyst engineer.
Need more from this tool? Send the inputs you used and what you need. A Civilyst engineer reads every message.
Send feedbackBNBC 2020 lists the basic wind speed V for 74 places in Table 6.2.8, for example Dhaka 65.7 m/s and Chittagong 80.0 m/s; elsewhere it comes from the wind map, Figure 6.2.1. The tool gives V for any site and the velocity pressure qz at each height (Eq. 6.2.17), with Kz, Kzt, Kd and the importance factor.
Last updated · Maintained by Md. Mohaimanul Islam (Rifat), civil engineer
| Town | V (m/s) |
|---|---|
| Dhaka | 65.7 |
| Chittagong (Chattogram) | 80.0 |
| Khulna | 73.3 |
| Rajshahi | 49.2 |
| Sylhet | 61.1 |
| Barisal (Barishal) | 78.7 |
| Rangpur | 65.3 |
| Mymensingh | 67.4 |
| Comilla (Cumilla) | 61.4 |
| Gazipur | 66.5 |
| Narayanganj | 61.1 |
| Bogra (Bogura) | 61.9 |
| Jessore (Jashore) | 64.1 |
| Cox's Bazar | 80.0 |
For a place the table does not list, V comes from the wind map, Figure 6.2.1.
Get the basic wind speed V for the site from BNBC 2020 Table 6.2.8, or from the wind speed map (Figure 6.2.1) where the site isn't listed. Then choose the exposure category, directionality and topographic factors and occupancy to get Kz and the velocity pressure qz at each height.
| Symbol | Unit | Quantity | System |
|---|---|---|---|
| m/s | metre per second | velocity | SI |
| m | metre | length | SI |
Bangladesh National Building Code (BNBC) 2020
Part 6, Chapter 2: Figure 6.2.1, Table 6.2.8, Tables 6.2.9 to 6.2.12 and Eq. 6.2.17
Geotechnical Calculations
Drop a pin anywhere in Bangladesh to get its BNBC 2020 seismic zone and Z value, with a warning near zone lines.
Structural Calculations
The BNBC 2020 design response spectrum, seismic design category, building period and base shear for a site, with storey forces and a drift check.
Structural Calculations
Development and lap lengths of deformed bars for every bar size, 8 to 32 mm, to BNBC 2020 or ACI 318-19: tension, top bars, laps, compression and hooks.